Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.967
Filtrar
1.
Sci Rep ; 14(1): 7758, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38565890

RESUMEN

Knowledge about anatomical details seems to facilitate the procedure and planning of prostatic artery embolization (PAE) in patients with symptomatic benign prostatic hyperplasia (BPS). The aim of our study was the pre-interventional visualization of the prostatic artery (PA) with MRA and the correlation of iliac elongation and bifurcation angles with technical success of PAE and technical parameters. MRA data of patients with PAE were analysed retrospectively regarding PA visibility, PA type, vessel elongation, and defined angles were correlated with intervention time, fluoroscopy time, dose area product (DAP), cumulative air kerma (CAK), contrast media (CM) dose and technical success of embolization. T-test, ANOVA, Pearson correlation, and Kruskal-Wallis test was applied for statistical analysis. Between April 2018 and March 2021, a total of 78 patients were included. MRA identified the PA origin in 126 of 147 cases (accuracy 86%). Vessel elongation affected time for catheterization of right PA (p = 0.02), fluoroscopy time (p = 0.05), and CM dose (p = 0.02) significantly. Moderate correlation was observed for iliac bifurcation angles with DAP (r = 0.30 left; r = 0.34 right; p = 0.01) and CAK (r = 0.32 left; r = 0.36 right; p = 0.01) on both sides. Comparing the first half and second half of patients, median intervention time (125 vs. 105 min.) and number of iliac CBCT could be reduced (p < 0.001). We conclude that MRA could depict exact pelvic artery configuration, identify PA origin, and might obviate iliac CBCT. Vessel elongation of pelvic arteries increased intervention time and contrast media dose while the PA origin had no significant influence on intervention time and/or technical success.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Masculino , Humanos , Próstata/diagnóstico por imagen , Próstata/irrigación sanguínea , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/terapia , Medios de Contraste , Embolización Terapéutica/métodos , Angiografía por Resonancia Magnética , Estudios Retrospectivos , Arterias/diagnóstico por imagen , Resultado del Tratamiento
2.
Artículo en Chino | MEDLINE | ID: mdl-38548399

RESUMEN

Objective: To explore the cutting scheme and clinical application effects of ultrathin thoracodorsal artery perforator flap assisted by color Doppler ultrasound. Methods: This study was a retrospective historical control study. From February 2017 to October 2019, 20 patients who were admitted to the Third Department of Orthopedics of Xingtai General Hospital of North China Medical and Health Group (hereinafter referred to as our department), met the inclusion criteria, and underwent repair of skin and soft tissue defects of extremities with ultrathin thoracodorsal artery perforator flap designed and harvested based on the surgeon's clinical experience were selected as control group, including 16 males and 4 females, aged (37±5) years. From November 2019 to December 2022, 21 patients who were admitted to our department, met the inclusion criteria, and underwent repair of skin and soft tissue defects of extremities with ultrathin thoracodorsal artery perforator flap designed and harvested under the assistance of color Doppler ultrasound were selected as ultrasound-assisted group, including 15 males and 6 females, aged (38±6) years. After debridement, the area of skin and soft tissue defects of extremities ranged 5.0 cm×4.0 cm to 19.0 cm×8.0 cm, and the area of thoracodorsal artery perforator flaps ranged 6.0 cm×5.0 cm to 20.0 cm×9.0 cm. The wounds in flap donor sites were closed directly. For patients in ultrasound-assisted group, the time and cost required for color Doppler ultrasound examination were recorded, and the number, type, and location of thoracodorsal artery perforator vessels detected by preoperative color Doppler ultrasound were compared with those of intraoperative actual detection. The time required for complete flap harvest of patients in 2 groups was recorded. On postoperative day (POD) 1, 3, 5, 7, and 14, the blood perfusion of flaps in the 2 groups of patients was assessed using a flap perfusion assessment scale. On POD 14, flap survival of patients in 2 groups was observed, and the percentage of flap survival area was calculated. In postoperative 6 months, satisfaction of patients with the treatment outcome in the 2 groups was assessed using 5-grade Likert scale, and the satisfaction rate was calculated. Results: For patients in ultrasound-assisted group, the time required for preoperative color Doppler ultrasound examination was (10.5±2.3) min, and the cost was 120 yuan; 21 thoracodorsal artery perforator vessels were detected and marked using preoperative color Doppler ultrasound, including 8 (38.10%) type 1 perforator vessels, 10 (47.62%) type 2 perforator vessels, and 3 (14.29%) type 3 perforator vessels; the number, type, and location of thoracodorsal artery perforator vessels detected preoperatively were consistent with those detected intraoperatively. The time required for complete flap harvest of patients in ultrasound-assisted group was (41±10) min, which was significantly shorter than (63±12) min in control group (t=6.32, P<0.05). On POD 1, 3, 5, 7, and 14, the blood perfusion scores of flaps of patients in ultrasound-assisted group were significantly better than those in control group (with t values of 6.67, 7.48, 8.03, 8.75, and 7.99, respectively P<0.05). On POD 14, only one patient in ultrasound-assisted group had partial flap necrosis and 6 patients in control group had complete or partial necrosis of the flap; the percentage of flap survival area of patients in ultrasound-assisted group was (99±8)%, which was significantly higher than (87±8)% in control group (t=4.57, P<0.05). In postoperative 6 months, there was no significant difference in the satisfaction rate of patients with the treatment outcome between the two groups (P>0.05). Conclusions: Preoperative color Doppler ultrasound is highly accurate in detecting the number, type, and location of perforator vessels. The cutting scheme of ultrathin thoracodorsal artery perforator flaps can be designed according to the different types of perforator vessels, with shorted flap cutting time and improved flap survival rate.


Asunto(s)
Colgajo Perforante , Procedimientos de Cirugía Plástica , Masculino , Femenino , Humanos , Colgajo Perforante/irrigación sanguínea , Estudios Retrospectivos , Arterias/diagnóstico por imagen , Ultrasonografía Doppler en Color , Necrosis
4.
Radiology ; 310(3): e231877, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38441098

RESUMEN

Background Prostatic artery embolization (PAE) is a safe, minimally invasive angiographic procedure that effectively treats benign prostatic hyperplasia; however, PAE-related patient radiation exposure and associated risks are not completely understood. Purpose To quantify radiation dose and assess radiation-related adverse events in patients who underwent PAE at multiple centers. Materials and Methods This retrospective study included patients undergoing PAE for any indication performed by experienced operators at 10 high-volume international centers from January 2014 to May 2021. Patient characteristics, procedural and radiation dose data, and radiation-related adverse events were collected. Procedural radiation effective doses were calculated by multiplying kerma-area product values by an established conversion factor for abdominopelvic fluoroscopy-guided procedures. Relationships between cumulative air kerma (CAK) or effective dose and patient body mass index (BMI), fluoroscopy time, or radiation field area were assessed with linear regression. Differences in radiation dose stemming from radiopaque prostheses or fluoroscopy unit type were assessed using two-sample t tests and Wilcoxon rank sum tests. Results A total of 1476 patients (mean age, 69.9 years ± 9.0 [SD]) were included, of whom 1345 (91.1%) and 131 (8.9%) underwent the procedure with fixed interventional or mobile fluoroscopy units, respectively. Median procedure effective dose was 17.8 mSv for fixed interventional units and 12.3 mSv for mobile units. CAK and effective dose both correlated positively with BMI (R2 = 0.15 and 0.17; P < .001) and fluoroscopy time (R2 = 0.16 and 0.08; P < .001). No radiation-related 90-day adverse events were reported. Patients with radiopaque implants versus those without implants had higher median CAK (1452 mGy [range, 900-2685 mGy] vs 1177 mGy [range, 700-1959 mGy], respectively; P = .01). Median effective dose was lower for mobile than for fixed interventional systems (12.3 mSv [range, 8.5-22.0 mSv] vs 20.4 mSv [range, 13.8-30.6 mSv], respectively; P < .001). Conclusion Patients who underwent PAE performed with fixed interventional or mobile fluoroscopy units were exposed to a median effective radiation dose of 17.8 mSv or 12.3 mSv, respectively. No radiation-related adverse events at 90 days were reported. © RSNA, 2024 See also the editorial by Mahesh in this issue.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Exposición a la Radiación , Humanos , Masculino , Anciano , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/terapia , Estudios Retrospectivos , Próstata/diagnóstico por imagen , Arterias/diagnóstico por imagen
5.
Br J Radiol ; 97(1156): 838-843, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38379411

RESUMEN

OBJECTIVES: To evaluate the clinical value of using a split-bolus contrast injection protocol in improving image quality consistency and diagnostic accuracy in lower extremity CT angiography (CTA). METHODS: Fifty (mean age, 66 ± 12 years) and 39 (mean age, 66 ± 11 years) patients underwent CTA in the lower extremity arteries using split-bolus and fixed-bolus injection schemes, respectively. The objective and subjective image quality of the 2 groups were compared and the diagnostic efficacy for the degree of vessel stenosis was compared using digital subtraction angiography as the gold standard. A P < .05 was considered statistically significant. RESULTS: In comparison with the fixed-bolus scheme, the split-bolus scheme greatly improved the consistency of image quality of the low extremities by significantly increasing the arterial enhancement (337.87 ± 64.67HU vs. 254.74 ± 71.58HU, P < .001), signal-to-noise ratio (22.58 ± 11.64 vs. 7.14 ± 1.98, P < .001), and contrast-to-noise ratio (37.21 ± 10.46 vs. 31.10 ± 15.40, P = .041) in the infrapopliteal segment. The subjective image quality was better (P < .001) and the diagnostic accuracy was higher in the split-bolus group than in the fixed-bolus group (96.00% vs. 91.67%, P < .05, for diagnosing >50% stenosis, and 97.00% vs. 89.10%, P < .05, for diagnosing occlusion) for the infrapopliteal segment arteries. CONCLUSIONS: Compared with the fixed-bolus injection scheme, the split-bolus injection scheme improves the image quality consistency and diagnostic accuracy especially for the infrapopliteal segment arteries in lower extremity CTA. ADVANCES IN KNOWLEDGE: (1) The split-bolus injection scheme of CTA of the lower extremity arteries improves the overall image quality, uniformity of contrast enhancement. (2) Compared with the fixed-bolus injection scheme, the split-bolus injection scheme especially improves the infrapopliteal segment arteries image quality and diagnostic efficacy.


Asunto(s)
Arterias , Angiografía por Tomografía Computarizada , Humanos , Persona de Mediana Edad , Anciano , Angiografía por Tomografía Computarizada/métodos , Constricción Patológica , Angiografía de Substracción Digital/métodos , Arterias/diagnóstico por imagen , Extremidad Inferior/diagnóstico por imagen , Extremidad Inferior/irrigación sanguínea , Medios de Contraste
6.
Magn Reson Med ; 91(6): 2320-2331, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38173296

RESUMEN

PURPOSE: Background suppression (BS) is recommended in arterial spin labeling (ASL) for improved SNR but is difficult to optimize in existing velocity-selective ASL (VSASL) methods. Dual-module VSASL (dm-VSASL) enables delay-insensitive, robust, and SNR-efficient perfusion imaging, while allowing efficient BS, but its optimization has yet to be thoroughly investigated. METHODS: The inversion effects of the velocity-selective labeling pulses, such as velocity-selective inversion (VSI), can be used for BS, and were modeled for optimizing BS in dm-VSASL. In vivo experiments using dual-module VSI (dm-VSI) were performed to compare two BS strategies: a conventional one with additional BS pulses and a new one without any BS pulse. Their BS performance, temporal noise, and temporal SNR were examined and compared, with pulsed and pseudo-continuous ASL (PASL and PCASL) as the reference. RESULTS: The in vivo experiments validated the BS modeling. Strong positive linear correlations (r > 0.82, p < 0.0001) between the temporal noise and the tissue signal were found in PASL/PCASL and dm-VSI. Optimal BS can be achieved with and without additional BS pulses in dm-VSI; the latter improved the ASL signals by 8.5% in gray matter (p = 0.006) and 12.2% in white matter (p = 0.014) and tended to provide better temporal SNR. The dm-VSI measured significantly higher ASL signal (p < 0.016) and temporal SNR (p < 0.018) than PASL and PCASL. Complex reconstruction was found necessary with aggressive BS. CONCLUSION: Guided by modeling, optimal BS can be achieved without any BS pulse in dm-VSASL, further improving the ASL signal and the SNR performance.


Asunto(s)
Angiografía por Resonancia Magnética , Sustancia Blanca , Angiografía por Resonancia Magnética/métodos , Marcadores de Spin , Arterias/diagnóstico por imagen , Sustancia Gris , Circulación Cerebrovascular , Encéfalo/diagnóstico por imagen
7.
Magn Reson Med ; 91(4): 1384-1403, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38181170

RESUMEN

PURPOSE: To present a theoretical framework that rigorously defines and analyzes key concepts and quantities for velocity selective arterial spin labeling (VSASL). THEORY AND METHODS: An expression for the VSASL arterial delivery function is derived based on (1) labeling and saturation profiles as a function of velocity and (2) physiologically plausible approximations of changes in acceleration and velocity across the vascular system. The dependence of labeling efficiency on the amplitude and effective bolus width of the arterial delivery function is defined. Factors that affect the effective bolus width are examined, and timing requirements to minimize quantitation errors are derived. RESULTS: The model predicts that a flow-dependent negative bias in the effective bolus width can occur when velocity selective inversion (VSI) is used for the labeling module and velocity selective saturation (VSS) is used for the vascular crushing module. The bias can be minimized by choosing a nominal labeling cutoff velocity that is lower than the nominal cutoff velocity of the vascular crushing module. CONCLUSION: The elements of the model are specified in a general fashion such that future advances can be readily integrated. The model can facilitate further efforts to understand and characterize the performance of VSASL and provide critical theoretical insights that can be used to design future experiments and develop novel VSASL approaches.


Asunto(s)
Arterias , Angiografía por Resonancia Magnética , Marcadores de Spin , Arterias/diagnóstico por imagen , Modelos Teóricos , Aceleración , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología
8.
Plast Reconstr Surg ; 153(3): 706-711, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37104463

RESUMEN

BACKGROUND: The purpose of this study was to determine the distribution of the angular artery (AA) in the medial canthal area with the aim of defining an arterial course to prevent AA injury during facial surgery in this region. METHODS: The authors dissected 36 hemifaces of 18 cadavers. The horizontal distance from the vertical level through the medial canthus to the AAs was measured. The AA course of each specimen was then recorded, and all of them were then superimposed to determine the AA course. The diameter and depth of the AA around the medial canthal area were also investigated using ultrasonography on living subjects. RESULTS: The horizontal distances from the medial canthus level and 2 cm below the medial canthus were 9.0 ± 2.0 mm (mean ± SD) and 1.9 ± 2.4 mm, respectively. The superimposed image demonstrated that most of the AAs were present inside the vertical line through the medial canthus. Ultrasonography indicated that the AA was 2.3 ± 0.9 mm below the skin and 1.7 ± 0.3 mm in diameter. CONCLUSIONS: The AA course was relatively constant along the nasojugal fold. The AAs were most often present between the middle of the medial canthus and the facial midline, but were very scarce in both the medial and lateral thirds. Knowledge of the detailed course of the AA may help surgeons to avoid arterial injury and decrease the risk of surgical morbidities around the nasal root and medial canthal area.


Asunto(s)
Aparato Lagrimal , Lesiones del Sistema Vascular , Humanos , Cara/diagnóstico por imagen , Cara/cirugía , Nariz/irrigación sanguínea , Ultrasonografía , Arterias/diagnóstico por imagen
9.
Cir Esp (Engl Ed) ; 102(2): 69-75, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37949364

RESUMEN

INTRODUCTION: While haemorrhoidal dearterialization and mucopexy are accepted as a valid alternative to haemorrhoidectomy, differences exist regarding the fixed or variable location of the arteries to be ligated. Our aim was to shed light on this issue of arterial distribution in candidates for surgery. METHODS: The study included consecutive patients diagnosed with Goligher grade III and IV haemorrhoids, who had undergone Doppler-guided haemorrhoidal artery ligation (DG-HAL) and rectoanal repair (RAR) at 2 medical centres in Spain. The main objective was to evaluate the number and 12-h clock locations of arterial ligatures necessary to achieve Doppler silence. RESULTS: In total, 146 patients were included: 111 (76%) men, and 35 (24%) women. Average age was 54 years (21-84). Grade III and grade IV haemorrhoids were diagnosed in 106 (72.6%) and 40 (27.4%) patients, respectively. The average number of ligatures per patient was 7 (range 2-12). Ligature percentages greater than 60% occurred at clock positions 7, 11, 10, 12, 9, and 1. The average number of mucopexies per patient was 3 (range 1-4). The most frequent mucopexy locations were the left posterior, right posterior, and right anterior octants. CONCLUSIONS: While the greatest frequency of arterial ligatures occurred in odd-numbered clock positions, non-negligible percentages occurred in even-numbered clock positions, which, in our opinion, makes the use of Doppler necessary, given that arterial distribution is not the same in all patients. We also noted that more ligatures and mucopexies were needed on the right half of the rectal circumference than on the left side, suggesting greater right-side vascularization.


Asunto(s)
Hemorreoidectomía , Hemorroides , Masculino , Humanos , Femenino , Persona de Mediana Edad , Hemorroides/diagnóstico por imagen , Hemorroides/cirugía , Ultrasonografía Intervencional , Recto/diagnóstico por imagen , Recto/cirugía , Recto/irrigación sanguínea , Arterias/diagnóstico por imagen , Arterias/cirugía
10.
J Vasc Interv Radiol ; 35(3): 409-415, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38008376

RESUMEN

PURPOSE: To evaluate the impact of virtual injection software (VIS) use during cone-beam computed tomography (CT)-guided prostatic artery embolization (PAE) on both patient radiation exposure and procedural time. MATERIALS AND METHODS: This institutional review board (IRB)-approved comparative retrospective study analyzed the treatment at a single institution of 131 consecutive patients from January 2020 to May 2022. Cone-beam CT was used with (Group 1, 77/131; 58.8%) or without VIS (Group 2, 54/131, 41.2%). Radiation exposure (number of digital subtraction angiography [DSA] procedures), dose area product (DAP), total air kerma (AK), peak skin dose (PSD), fluoroscopy time (FT), and procedure time (PT) were recorded. The influences of age, body mass index, radial access, and use of VIS were assessed. RESULTS: In bivariate analysis, VIS use (Group 1) showed reduction in the number of DSA procedures (8.6 ± 3.7 vs 16.8 ± 4.3; P < .001), DAP (110.4 Gy·cm2 ± 46.8 vs 140.5 Gy·cm2 ± 61; P < .01), AK (642 mGy ± 451 vs 1,150 mGy ± 637; P = .01), PSD (358 mGy ± 251 vs 860 mGy ± 510; P = .001), FT (35.6 minutes ± 15.4 vs 46.6 minutes ± 20; P = .001), and PT (94.6 minutes ± 41.3 vs 115.2 minutes ± 39.6, P = .005) compared to those in Group 2. In multivariate analysis, AK, PSD, FT, and PT reductions were associated with VIS use (P < .001, P < .001, P = .001, and P = .006, respectively). CONCLUSIONS: The use of VIS during PAE performed under cone-beam CT guidance led to significant reduction in patient radiation exposure and procedural time.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Exposición a la Radiación , Masculino , Humanos , Embolización Terapéutica/efectos adversos , Próstata/diagnóstico por imagen , Próstata/irrigación sanguínea , Estudios Retrospectivos , Hiperplasia Prostática/terapia , Arterias/diagnóstico por imagen , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Programas Informáticos , Tomografía Computarizada de Haz Cónico/efectos adversos , Tomografía Computarizada de Haz Cónico/métodos , Dosis de Radiación , Fluoroscopía
11.
Am J Hypertens ; 37(1): 24-32, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37638873

RESUMEN

BACKGROUND: Preeclampsia (PE) is associated with increased cardiovascular risk. Recent data have shown worse left ventricular remodeling and diastolic function in women with PE and persistent hypertension (HTN). We performed a comprehensive arterial hemodynamic assessment to evaluate the contribution of persistent HTN on arterial health after PE. METHODS: We recruited 40 women with PE history and 40 age-matched controls (6 months to 6 years postpartum). We evaluated arterial hemodynamics with validated techniques combining applanation tonometry and transthoracic echocardiography, comparing three groups: previous PE with persistent HTN (PE-HTN), previous PE with normalized blood pressure (PE-noHTN) and controls, using multivariable linear regression adjusted for age, body surface area, heart rate, diabetes, smoking history, creatinine, and gravidity. RESULTS: Eight (20%) of the post-PE women had persistent HTN. Mean age was 35.8 ±â€…3.9 years, median number of pregnancies was 2 (range 1-7), and time since last pregnancy 2.1 (range 0.5-5.7) years (not different between groups, P > 0.05). Compared to controls and to PE-noHTN, PE-HTN had higher aortic stiffness, wave reflections, pulsatile, and steady arterial load (P < 0.05 for each). Among PE-noHTN, aortic stiffness, wave reflections and steady arterial load were worse than controls (P < 0.05 for each), with smaller effect sizes. CONCLUSIONS: This is the most comprehensive assessment of arterial hemodynamics and first to demonstrate the contribution of persistent HTN on worse arterial health following PE. Since measures of arterial health are associated with cardiovascular events in the population, the combination of previous PE and chronic HTN may represent a higher risk subgroup who could benefit from targeted prevention strategies.


Asunto(s)
Hipertensión , Preeclampsia , Rigidez Vascular , Embarazo , Humanos , Femenino , Adulto , Preeclampsia/diagnóstico , Preeclampsia/epidemiología , Arterias/diagnóstico por imagen , Presión Sanguínea/fisiología , Envejecimiento , Rigidez Vascular/fisiología
12.
MAGMA ; 37(1): 53-68, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37768433

RESUMEN

OBJECTIVES: One challenge in arterial spin labeling (ASL) is the high variability of arterial transit times (ATT), which causes associated arterial transit delay (ATD) artifacts. In patients with pathological changes, these artifacts occur when post-labeling delay (PLD) and bolus durations are not optimally matched to the subject, resulting in difficult quantification of cerebral blood flow (CBF) and ATT. This is also true for the free lunch approach in Hadamard-encoded pseudocontinuous ASL (H-pCASL). MATERIAL AND METHODS: Five healthy volunteers were scanned with a 3 T MR-system. pCASL-subbolus timing was adjusted individually by the developed adaptive Walsh-ordered pCASL sequence and an automatic feedback algorithm. The quantification results for CBF and ATT and the respective standard deviations were compared with results obtained using recommended timings and intentionally suboptimal timings. RESULTS: The algorithm individually adjusted the pCASL-subbolus PLD for each subject within the range of recommended timing for healthy subjects, with a mean intra-subject adjustment deviation of 47.15 ms for single-shot and 44.5 ms for segmented acquisition in three repetitions. DISCUSSION: A first positive assessment of the results was performed on healthy volunteers. The extent to which the results can be transferred to patients and are of benefit must be investigated in follow-up studies.


Asunto(s)
Arterias , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Marcadores de Spin , Reproducibilidad de los Resultados , Arterias/diagnóstico por imagen , Circulación Cerebrovascular/fisiología
14.
NMR Biomed ; 37(2): e5048, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37798964

RESUMEN

Paravascular cerebrospinal fluid (pCSF) surrounding the cerebral arteries within the glymphatic system is pulsatile and moves in synchrony with the pressure waves of the vessel wall. Whether such pulsatile pCSF can infer pulse wave propagation-a property tightly related to arterial stiffness-is unknown and has never been explored. Our recently developed imaging technique, dynamic diffusion-weighted imaging (dynDWI), captures the pulsatile pCSF dynamics in vivo and can explore this question. In this work, we evaluated the time shifts between pCSF waves and finger pulse waves, where pCSF waves were measured by dynDWI and finger pulse waves were measured by the scanner's built-in finger pulse oximeter. We hypothesized that the time shifts reflect brain-finger pulse wave travel time and are sensitive to arterial stiffness. We applied the framework to 36 participants aged 18-82 years to study the age effect of travel time, as well as its associations with cognitive function within the older participants (N = 15, age > 60 years). Our results revealed a strong and consistent correlation between pCSF pulse and finger pulse (mean CorrCoeff = 0.66), supporting arterial pulsation as a major driver for pCSF dynamics. The time delay between pCSF and finger pulses (TimeDelay) was significantly lower (i.e., faster pulse propagation) with advanced age (Pearson's r = -0.44, p = 0.007). Shorter TimeDelay was further associated with worse cognitive function in the older participants. Overall, our study demonstrated pCSF as a viable pathway for measuring intracranial pulses and encouraged future studies to investigate its relevance with cerebrovascular functions.


Asunto(s)
Rigidez Vascular , Humanos , Hidrodinámica , Arterias/diagnóstico por imagen
15.
J Vasc Interv Radiol ; 35(4): 487-496.e6, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38128722

RESUMEN

Genicular artery embolization is increasingly recognized as a safe and effective treatment option for symptomatic knee osteoarthritis and recurrent hemarthrosis after total knee arthroplasty. Genicular arteries are an essential contributor to vascular supply for the knee joint and demonstrate considerable variability. Familiarity with the anatomy and common variations is critical for preprocedural planning, accurate target selection, and minimizing adverse events in transarterial embolization procedures. This review aimed to provide a detailed discussion of the genicular artery anatomy that is relevant to interventional radiologists performing genicular artery embolization.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/irrigación sanguínea , Rodilla/irrigación sanguínea , Arterias/diagnóstico por imagen , Artroplastia de Reemplazo de Rodilla/efectos adversos , Extremidad Inferior
17.
Comput Methods Programs Biomed ; 244: 107983, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38157828

RESUMEN

BACKGROUND AND OBJECTIVE: This study aims to assess the dynamic impact of non-Newtonian cerebral arterial circulation on electrical conductivity within a realistic multi-compartment head model. Evaluating this research question is crucial and challenging due to its relevance to electrophysiological modalities like transcranial electrical stimulation (tES), electro-/magnetoencephalography (EEG/MEG), and electrical impedance tomography (EIT). In these modalities, accurate forward modeling depends on the electrical conductivity, which is affected by complex tortuous vessel networks, limited data acquisition in Magnetic Resonance Imaging (MRI), and non-linear blood flow phenomena, including shear rate and viscosity in non-Newtonian fluid. METHODS: To obtain an approximation for the blood concentration, we first use Navier-Stokes equations (NSEs) to solve for the pressure and velocity of the blood in the major vessels. Then Fick's law is used to solve for the blood concentration in the tissues. Finally, Archie's law is used to estimate the electrical conductivity distribution based on the blood concentration. RESULTS: The results, obtained with an open 7 Tesla MRI dataset, suggest that a dynamic model of cerebral blood flow (CBF) for both arterial and microcirculation can be established; we find blood pressure and electrical conductivity distributions given a numerically simulated pulse sequence and approximate the blood concentration and electrical conductivity inside the brain based on those. CONCLUSIONS: Our model provides an approximation of the dynamical blood flow and the corresponding electrical conductivity distribution in the different parts of the brain. The advantage of our approach is that it is applicable with limited a priori information about the blood flow and with an arbitrary head model distinguishing the arteries.


Asunto(s)
Arterias , Hemodinámica , Arterias/diagnóstico por imagen , Magnetoencefalografía/métodos , Circulación Cerebrovascular , Conductividad Eléctrica
18.
PeerJ ; 11: e16439, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38050605

RESUMEN

Purpose: Anastomosis between posterior superior alveolar artery and infraorbital artery can go through bony canal in the lateral wall of the maxilla. This artery is called alveolar antral artery. It can complicate lateral sinus lift procedure by bleeding and hemosinus formation or bone graft wash out. The artery can also go in soft tissues where is not visible on cone beam computed tomography. In previous studies, the relation of this artery to sinus floor or alveolar process was measured. These structures are highly unstable during lifetime and after tooth loss. The aim of this study is to study presence and relations of bony canal in the lateral maxillary wall, to characterize the group of patients which is more likely to have bone canal in the lateral maxilla. The aim and the novelty of this study is the describing of the relationship of the bony canal to the more stable structure of hard palate and describing the relation of presence of bony canal on width of maxillary sinus, and to facilitate the prediction of presence of the alveolar antral artery. Materials: The cone beam computed tomography scans of the patients (251 in number) of the university hospital were examined for presence of alveolar antral artery (148 was fulfilled inclusion criteria), patient were characterized by gender, age, and sinus type (wide, average, narrow). The diameter of the bony canal and its relation to the level of sinus floor and hard palate were measured. Results: The cone beam computed tomography scans of 148 patients, out of it 55 man (37,2%) and 93 women (62,8%). Bony canal containing alveolar anastomosis was found in 69 cases (57,0%). Presence of the bony canal in the lateral wall of maxillae showed statistical probability depending on age with p = 0, 064 according to Mann-Whitney test. The older patients have more likely the bony canal. The presence of the alveolar antral artery was found more likely in the wide sinuses. The hard palate level can serve as a prediction point of alveolar antral artery only in first molar and second premolar region. In accordance with previous studies the width of bony canal is significantly higher in group of man (p = 0, 015). There was found a correlation between smaller distance of bony canal from sinus floor in the presence of teeth (p = 0, 067). After tooth loss the distance between sinus floor and bony canal increases, but the distance of bony canal to hard palate level stays constant. This can be explained hypothetically so that periodontal ligaments and root surface acts as a barrier for sinus pneumatization. Conclusion: Lateral sinus lifting in some cases can be unenviable, the knowledge about alveolar antral artery anatomy can reduce the risk of arterial bleeding. The cone-beam computed tomography is a routine examination prior to augmentation surgery and therefore the data obtained from it has an impact on clinical practice.


Asunto(s)
Elevación del Piso del Seno Maxilar , Pérdida de Diente , Masculino , Humanos , Femenino , Tomografía Computarizada de Haz Cónico/métodos , Arterias/diagnóstico por imagen , Proceso Alveolar/diagnóstico por imagen
19.
Medicina (Kaunas) ; 59(12)2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38138225

RESUMEN

Background and Objectives: The purpose of the current paper is to present our study on the variability in the prostatic artery origin, discuss the less frequent origins, and present the challenges of the prostatic artery embolization (PAE) procedure, thus aiding young interventional radiologists. Materials and Methods: We studied the origins of the prostatic artery on digital subtraction angiography (DSA) examinations from PAE procedures on 35 male pelvises (70 hemi-pelvises). Results: Our study has demonstrated that the most frequent origin of the prostatic artery (PA) is the internal pudendal artery (IPA), 37.1%, followed by the anterior gluteal trunk, 27.1%, and the superior vesical artery (SVA), 21.4%. Less frequent origins are the obturator artery (OBT), 11.4%, and the inferior gluteal artery (IGA), 2.8%. Conclusions: Compared to other studies, we notice some differences in the statistical results, but the most frequent origins remain the same. What is more important for young interventional radiologists is to be aware of all the possible origins of the PA in order to be able to offer a proper treatment to their patients. The important aspect that will ensure the success of the procedure without post-procedural complications is represented by the successful embolization of the targeted prostatic parenchyma.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Humanos , Masculino , Próstata/diagnóstico por imagen , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/terapia , Hiperplasia Prostática/complicaciones , Embolización Terapéutica/métodos , Estudios Retrospectivos , Arterias/diagnóstico por imagen , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...